ST802 Optical Loss Tester accurately tests ORL of 1310nm and 1550nm wavelength. It can be widely operated to test connector and components of telecommunication, CATV and WAN |
|
Key Features and Functions... |
|
· Optical loss precise measurement · Automatic wavelength identification · Absolute power test dBm · Dual wavelength stable laser source · Memory capacity of 50 data items; · High contrast backlit display · Small size, simple button operation · 6-minutes automatic power off without button operation and energy-save design |
|
Technical Specifications... |
|
Optical power meter module parameters |
|
|
Wavelength range (nm) |
800~1600 |
|
Detector type |
InGaAs |
|
Power range (dBm) |
-50 to +3 |
|
Uncertainty |
±5% |
|
Resolution (dBm) |
0.01 |
|
Laser source module parameters |
|
|
Emitter type |
Fabry_Perot LD |
|
Dual wavelength switch (nm) |
1310±20, 1550±20 |
|
Spectral width (nm) |
≤5 |
|
Output optical power (dBm) |
≥-12 |
|
Power Stability (dB) (Short time) |
≤±0.05/15min |
|
Power Stability (dB) (Long time) |
≤±0.1/8hs |
|
Optical loss module parameters |
|
|
Optical test interface |
FC/APC |
|
Working wavelength (nm) |
1310, 1550 |
|
Test range (dB) |
0~50 |
|
Accuracy (dB) |
±1.5 |
|
General specifications |
|
|
Working temperature (℃) |
0~40 |
|
Storage temperature(℃) |
-10~+60 |
|
Weight (kg) |
0.2 |
|
Dimension (mm) |
160×76×28 |
|
Battery |
9V/160mAh NI-MH rechargeable battery |
|
Battery working duration |
2h In optical loss tester status 4h In stable laser source status 4h In optical power status |